Skip to content
Back

GutCheck

AI Research

A two-week comparison of SAM 3.1, DINOv3, and PraNet on colonoscopy polyp segmentation. The 2020 specialist still wins across datasets, and changing one prompt word gains 13.5 Dice points.

Python
PyTorch
Computer Vision
Medical Imaging
SAM
DINOv3

Key features

  • PraNet, from 2020, scores 0.905 Dice on a second dataset. SAM 3.1 with LoRA scores 0.764 and DINOv3 with a trained decoder scores 0.778
  • PraNet and DINOv3 run at 54 frames per second on an H100. SAM 3.1 runs at 16
  • Changing the SAM 3.1 prompt from "polyp" to "growth" lifts cross-dataset Dice from 0.569 to 0.705
  • No other word worked. "tumor" fell to 0.36 and "lesion" to 0.15
  • Of SAM 3.1's 42 worst failures, only 2 are also bad for PraNet. Most come from the dark ring around the scope's view
  • Trained on Kvasir-SEG and tested on Kvasir and CVC-ClinicDB, on one H100

The question was whether six years of progress in vision foundation models helps on a medical imaging task. I compared four approaches on finding polyps in colonoscopy images: SAM 3.1 with a text prompt, SAM 3.1 adapted with LoRA, DINOv3 with a small trained decoder, and PraNet, a specialist model from 2020.

The result

On the dataset they trained on, the new models get close. DINOv3 scores 0.895 Dice and PraNet 0.898. On a second dataset none of them had seen, PraNet scores 0.905 and nothing else passes 0.78. The specialist is also about three times faster than SAM.

Two things I didn’t expect

SAM 3.1 doesn’t fail on hard polyps. It fails on framing. Many colonoscopy images show a round view inside a black ring, and that ring is what predicts a bad result.

The other was the prompt. Asking SAM 3.1 for “growth” where I had asked for “polyp” gained 13.5 Dice points on the second dataset, with nothing else changed. It helped 12 images by a wide margin and hurt none by the same margin. My guess is that the model has seen the word “growth” far more often.